Rivacold-products

Rivacold systems

Wall mounted blocksystems series FA

Plug-in and saddle version.

Refrigeration output:
LBP: from 639 W to 2936 W
MBP: from 830 W to 3871 W
Cold room volume:
LBP: from 3 m³ to 41 m³
MBP: from 4 m³ to 45 m³
Rivacold systems

Wall mounted blocksystems series SV

Plug-in with flat evaporator.

Refrigeration output:
LBP: from 605 W to 1139 W
MBP: from 730 W to 1417 W
Cold room volume:
LBP: from 3 m³ to 8 m³
MBP: from 4 m³ to 10 m³
Rivacold systems

Wall mounted blocksystems series P

Plug-in version.

Refrigeration output:
LBP: from 3497 W to 19474 W
MBP: from 4998 W to 22117 W
Cold room volume:
LBP: from 51 m³ to 568 m³
MBP: from 54 m³ to 329 m³
Rivacold systems

Wall mounted blocksystems series CT

Plug-in version with weather proof housing for mounting outdoors.

Refrigeration output:
LBP: from 726 W to 3174 W
MBP: from 1048 W to 4129 W
Cold room volume:
LBP: from 3 m³ to 45 m³
MBP: from 6 m³ to 49 m³
Rivacold systems

Wall mounted blocksystems series BX

Plug-in version with weather proof housing for mounting outdoors.

Refrigeration output:
LBP: from 17153 W to 32437 W
MBP: from 23984 W to 47306 W
Cold room volume:
LBP: from 487 m³ to 1047 m³
MBP: from 444 m³ to 931 m³
#######################
Rivacold systems

Split blocksystems series FS

Condensing units with wall mounting.

Refrigeration output:
LBP: from 607 W to 2808 W
MBP: from 840 W to 3779 W
Cold room volume:
LBP: from 3 m³ to 39 m³
MBP: from 4 m³ to 43 m³
Rivacold systems

Split blocksystems series SP

Condensing units with wall mounting.

Refrigeration output:
LBP: from 3497 W to 19474 W
MBP: from 4998 W to 22117 W
Cold room volume:
LBP: from 51 m³ to 568 m³
MBP: from 54 m³ to 329 m³
Rivacold systems

Split blocksystems series ST

Condensing units for ceiling- or floor mounting.

Refrigeration output:
LBP: from 604 W to 28018 W
MBP: from 857 W to 37389 W
Cold room volume:
LBP: from 2 m³ to 973 m³
MBP: from 5 m³ to 604 m³
Rivacold systems

Split blocksystems series THU RVC

Condensing units with weaterproof housing soundproof and hermetic compressors.

Refrigeration output:
LBP: from 479 W to 3870 W
MBP: from 844 W to 10220 W
Cold room volume:
LBP: from 2 m³ to 63 m³
MBP: from 5 m³ to 139 m³
Rivacold systems

Split blocksystems series THC RVC

Condensing units with weatherproof housing soundproof and Scroll compressors.

Refrigeration output:
LBP: from 1891 W to 8733 W
MBP: from 3678 W to 9923 W
Cold room volume:
LBP: from 19 m³ to 138 m³
MBP: from 37 m³ to 138 m³
Rivacold systems

Split blocksystems series SX RVC

Condensing units with weatherproof housing and semi-hermetic compressors.

Refrigeration output:
LBP: from 3579 W to 43726 W
MBP: from 4138 W to 60984 W
Cold room volume:
LBP: from 85 m³ to 1501 m³
MBP: from 57 m³ to 1218 m³